Pre-wired magnetic loop: how to detect cars at the parking barrier

Automatic barriers

Pre-wired magnetic loop: how to detect cars at the parking barrier

A pre-wired magnetic loop detects the presence of a vehicle above it and transmits the signal to the automatic barrier. Thus, the arm does not descend over the car, and the barrier can close itself after passing. The pre-wired version comes with loop and tail already formed, so the assembly gets faster and cleaner.

In short: choose a loop of 5 m or 8 m after the width of the band, bind it to a BFT RME detector and fit it on the roadway, with the tail to the barrier.

Do you need help choosing?

Tell us what you need and we'll send you the offer on the same working day.

A well-chosen loop makes parking safer and more fluid. The MAGNETIC LOOP 5MT version matches the usual bands, and 8MT covers wider entries. Both have a 10 m tail and are attached to an RME detector. Combine loop with barrier photocells for double protection. Test the detection after mounting with the usual vehicles of the location. Now choose the right prewired magnetic loop from the category of parking accessories of our store.

A pre-wired magnetic loop is one of the most discreet accessories of a parking barrier. It is buried in asphalt or concrete and feels the metal mass of the vehicle above it. Therefore, the barrier knows when a car has reached its right and when it has passed completely.

Category parking accessories You find two BFT variants, with different loop lengths. Below we explain how it works, what detector it needs and how you choose the right length.

How a prewired magnetic loop works

The loop means, in fact, a few wired pins sitting in a rectangular contour under the roadway. A detector sends through it a weak electrical signal and tracks the formed field. When a car enters above, its metal mass modifies this field. Thus, the detector closes a contact and announces the central barrier.

At a pre-wired magnetic loop, the loop wires and the link tail are already formed and protected. In other words, no longer manually wrap the coils in the ditch. It also reduces the risk of winding errors leading to unstable detections.

What ‘tail' and ‘bull' mean in the product file

The loop is the active part, the one under the vehicle. The tail represents the loop-detector connection cable, usually mounted in the body of the barrier. At the BFT models in the store, the tail measures 10 m. So, you have a good cable reserve even if the barrier stands a few meters from the gangway.

BFT magnetic loop: MAGNETIC LOOP 5MT and 8MT

Our range includes two variants of prewired magnetic loop, both with high sensitivity, according to the manufacturer.

The length of the loop represents the perimeter of the buried contour. For example, a 5 m loop can form a rectangle of about 2 x 0.5 m. Instead, a loop of 8 m allows a wider contour, useful for wide bands or for self-utilization.

Difference from the classic SPIRA loop

In the category of detectors found and magnetic loop BFT SPIRA 2x1 m. This has a fixed format of 2 x 1 m. However, a pre-wired magnetic loop provides integrated long tail and a more orderly installation on the yard.

Detector: piece without which loop does not work

The loop alone does not transmit anything to the barrier. She needs a metal mass detector, which reads the field variations and turns them into commands. BFT offers two options in the category Metal detectors:

  • Detector BFT RME 1 BT work at 24 V and read only one channel.
  • Version BFT RME 2 works at 230 V and manages two channels.

A two-channel detector can read two loops, for example one before and one after the barrier. Therefore, the power station also knows the direction of the vehicle. Choose the voltage of the detector after the barrier center, because the power supply has to match.

Where you use a prewired magnetic loop

The most common application remains the parking barrier. However, the loop also finds room for other types of controlled access.

  • Automatic closing of the barrier after the car has passed completely.
  • Vehicle protection, because the arm does not come down as long as the loop feels metal.
  • Automatic opening at exit from the parking lot, without remote control.
  • Numbering of vehicles at entry into an enclosure with a compatible power station.

For complete systems with barriers, arms and accessories, see BFT barrier kits. Thus, a pre-wired magnetic loop completes a unitary thought system, not a piece added later.

Mounting on the roadway, step by step

The assembly requires attention, because the loop then remains hidden under asphalt for good years. First, you mark the outline on the middle of the passing tape. Then I cut a narrow ditch with the disc at the depth indicated by the manufacturer. Later, you sit the loop, seal the ditch with a suitable material and take the tail to the barrier through the protective tube.

  • Keep away from large metal armor, home caps or power cables.
  • Turn the tail on the path to the detector, to reduce interference.
  • Avoid areas with cracks or mobile dals, which can cut the cable over time.

The rules for the movement and signalling of public bodies are based on the legislation in force, which you can consult on National legislative portal. In the end, the exact configuration shall be established after the parking project.

Mistakes affecting a pre-wired magnetic loop

Most problems occur at assembly, not at product. It is therefore worth knowing the situations that produce false or failed detections.

  • The contour sitting too close to a metal grid or a channel cap.
  • The tail left unturned beside power lines.
  • The ditch filled with a material that cracks at ice.
  • The sensitivity of the detector is set too high for that area.

On the other hand, a properly mounted pre-wired magnetic loop works steady without any hard-on adjustment. However, after repair work on the roadway, check the detection again.

The post-assembly test follows a few simple steps. First, check the detector to see if the loop appears connected and stable. Then slowly pass with a car over it and track the signal. Then repeat the test with the highest vehicle using the input. Thus, find out whether the chosen prewired magnetic loop covers all real situations.

Frequently asked questions: pre-wired magnetic loop

Replaces a prewired magnetic loop with the photocells?

Nope. The loop detects vehicles, but does not feel pedestrians or light bicycles. Therefore, we recommend the use of both devices.

What length do I choose for a regular band?

For cars, the 5 m range usually covers a standard band. At wide entrances or for high vehicles, choose the option of 8 m.

Can I use the loop and a sliding gate?

Yeah, with a sensor compatible with the power station. Thus, the gate stays open while the car stays on the loop.

Find both options in the category parking accessories, together with the technical information of each loop. The BFT Store team helps you choose prewired magnetic loop and the right detector for your barrier.

Recent articles

All articles

Cookie settings

Choose which categories you accept. Strictly necessary cookies are always active; the others start only with your consent and you can change them at any time. Cookie policy

They make the site work: shopping cart, favourites, customer account sign-in, form security and remembering your cookie choice. They cannot be disabled.

Remembers recently viewed products so you can find them easily. The data stays only in your browser.

Shows us which pages are visited and how the site is used, so we can improve it (Google Analytics).